- Airsense 10 manual
Additional information regarding the FCC Rules for this device can be found on www. Page Limited Warranty ResMed. ResMed recommends that the AirSense 10 device be inspected and serviced by an authorized ResMed Service Centre if there is any sign of wear or concern with device function. Otherwise, service and inspection of the products generally should not be required during their design life. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components.
Page 22 See www. For patent information, see www. Patent and Trademark Office. Print page 1 Print document 23 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals?
Sign In OR. Als u een droge neus of mond krijgt, verhoogt u de vochtigheid. Als u vocht in uw masker krijgt, verlaagt u de vochtigheid. U kunt het vochtigheidsniveau instellen op Uit of op een waarde van 1 tot 8, waarbij 1 de laagste vochtigheidsinstelling is en 8 de hoogste vochtigheidsinstelling. Page 96 Verzorging van het apparaat Het is belangrijk om het AirSense apparaat regelmatig te reinigen, om te zorgen dat u optimale therapie ontvangt. De volgende paragrafen helpen u bij het uit elkaar halen, reinigen, controleren en weer in elkaar zetten van het apparaat.
Controleren U moet de bevochtiger, de luchtslang en het luchtfilter regelmatig op schade controleren. Reizen U kunt het AirSense apparaat overal mee naartoe nemen.
Medische hulpmiddelen worden niet meegerekend in het maximale gewicht van uw handbagage. Op www. Stel het vochtigheidsniveau bij. Mijn mond is heel droog en oncomfortabel Misschien ontsnapt er lucht door uw mond. Schakel de vliegtuigmodus uit. Zie Reizen per vliegtuig.
Gegevensoverdracht is niet ingeschakeld voor uw apparaat. Neem contact op met uw zorgverlener om de gegevensoverdrachtservice te laten inschakelen. Mijn scherm en knoppen knipperen Software-upgrade wordt uitgevoerd. Controleer het luchtfilter en vervang het als er sprake is van verstopping. Maak de voedingseenheid los en sluit deze weer aan om het apparaat opnieuw op te starten. Misschien is de luchtslang verstopt.
Controleer de luchtslang en verwijder eventuele verstoppingen. Aanpassen van het masker zonder dat het apparaat lucht blaast, kan leiden tot weer inademen van uitgeademde lucht. Zorg dat de ventilatiegaten in het masker niet worden afgedekt en niet worden geblokkeerd om de stroming van verse lucht in het masker te handhaven.
Page Technische Specificaties voor gebruik in woonwijken, winkels en lichte industrie. Het verdient aanbeveling mobiele communicatieapparaten op minimaal 1 m afstand van het apparaat te houden.
Informatie over de elektromagnetische straling en immuniteit van dit ResMed-apparaat kunt u vinden op www. Draadloze module Page Beperkte Garantie Onderhoudsbeurten Het AirSense apparaat is bedoeld om veilig en betrouwbaar te werken als hij volgens de door ResMed gegeven instructies gebruikt wordt. ResMed raadt aan om het AirSense apparaat door een geautoriseerd ResMed-servicecentrum te laten inspecteren en repareren als zich tekenen van slijtage voordoen of het apparaat niet goed lijkt te werken.
Page ResMed is niet verantwoordelijk voor eventuele incidentele schade of gevolgschade die beweerdelijk het gevolg zou zijn van de verkoop, installatie of het gebruik van enig ResMed-product. In sommige regio[APOS]s of landen is de uitsluiting of beperking van incidentele schade of gevolgschade niet toegestaan, daarom is de bovengenoemde beperking misschien niet op u van toepassing.
Print page 1 Print document pages. Rename the bookmark. Delete bookmark? Move the switch on the SD Card from the lock position to the unlock position and then re-insert it. Page Technical Specifications , for residential, commercial and light industry environments. It is recommended that mobile communication devices are kept at least 1 m away from the device. Information regarding the electromagnetic emissions and immunity of this ResMed device can be found on www.
Page 20 Pneumatic flow path 1. Flow sensor 2. Blower 3. Pressure sensor 4. Mask 5. Air tubing 6. Humidifier 7. Device 8. Inlet filter Design life Device, power supply unit: 5 years Cleanable humidifier: 2. Measurement system uncertainties ResMed recommends that the AirSense 10 device be inspected and serviced by an authorised ResMed Service Centre if there is any sign of wear or concern with device function.
Otherwise, service and inspection of the products generally should not be required during their design life. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components. Page 31 Regulacja czasu narastania: 1. Page 33 3. Page 34 Wymiana filtra powietrza: 1.
Slight discoloration may occur and is acceptable. Packaging and storage Store in a dry, dust-free environment away from direct sunlight. Page Decontaminating 1. Clean all components with a soft bristled brush for one minute while soaking in detergent solution see table below. Pay particular attention to all crevices and cavities. Page Reassembling Reassembling The following instructions provide guidance on how to correctly reassemble the air outlet and the water tub.
To reassemble the air outlet 1. Hold the air outlet with the seal pointing to the left and the clip pointing forward. Page 30 To reassemble the water tub lid: 1. Insert one side of the lid into the pivot hole of the base. Slide the other side down the ridge until it clicks into place.
Page Data Management And Therapy Compliance Data management and therapy compliance For therapy compliance management, the AirSense 10 device stores patient data on the device and has the ability to transfer it remotely to the care provider.
Detailed Data such as snore and pulse rate, as well as high resolution flow and pressure data, are stored on the SD card. Data can be transmitted to therapy management software either remotely via cellular communication, or via SD card. For information on purchasing, contact your ResMed representative. Do this by turning the Humidity Level to Off. Page Troubleshooting Troubleshooting If there is a problem, try the following suggestions. If you are not able to fix the problem, contact your local ResMed dealer or ResMed office.
Do not open the device. Page 35 SmartStart is enabled, but the device does not automatically stop when the patient removes their mask Incompatible mask being used. Only use equipment recommended by ResMed. Contact ResMed or see www. If the patient is using a nasal pillows mask with set pressure Page Device Messages All other error messages, for example, System fault, refer to user guide, Error 0XX An unrecoverable error has occurred on the device.
Contact your local ResMed dealer or ResMed office.
ResMed Airsense 10 Manual & Instructions
Hide thumbs. Table Of Contents. Quick Links. Table of Contents. Previous Page. Next Page. Page 3 Reprocessing Note: Make sure all parts and accessories used with the device are compatible. For compatibility information, refer to www. Page 8: Flow Limitation Flow limitation As the upper airway begins to collapse, the shape of the inspiratory flow-time curve changes.
The AirSense 10 recognizes and treats traditional as well as less common flow-limited breath wave forms. Snore Snoring is sound generated by vibrations of the walls of the upper airway. It is often preceded by flow limitation or a partial obstruction of the airway.
Page Cpap Mode If two apneas occur within a minute, the pressure reached in response to the second apnea will become the new minimum treatment pressure until the next treatment session. When an apnea has been detected, small oscillations in pressure 1 cm H O peak-to-peak at 4 Hz are added to the current device pressure.
Increasing respiratory effort will be seen as airflow limitation. Page Comfort Features Comfort features Ramp Designed to make the beginning of treatment more comfortable, ramp is available in all modes.
In AutoSet and AutoSet for Her mode, ramp time defines the period during which the pressure gradually increases from a lower more comfortable start pressure to the minimum treatment pressure before the auto-adjusting algorithm commences. Page Climate Control Climate Control Climate Control is an intelligent system that controls the humidifier and the ClimateLineAir heated air tubing to deliver constant, comfortable temperature and humidity levels during therapy.
Designed to prevent dryness of the nose and mouth, it maintains the set temperature and relative humidity while you sleep.
Page Setup 5. Close the water tub and insert it into the side of the device. Connect the free end of the air tubing firmly onto the assembled mask. See the mask user guide for detailed information. Recommended masks are available on www. Page Supplemental Oxygen Antibacterial filters increase resistance in the air circuit and may affect accuracy of displayed and delivered pressure, particularly at high flows.
The Home screen is displayed with an unlock icon in the top right corner of the screen. Page Setting The Date And Time The settings can be changed in different ways depending on the type of screen: Turn the dial to edit live in Turn the dial to change Select from a list of options. Setting the date and time Before you set up a new patient and start therapy for the first time, make sure you set the correct local date and time on the device. Refer to Mask Device Compatibility List on www.
Page Starting Therapy Starting therapy 1. Direct the patient to fit their mask. Therapy will begin and the Sleep Report screen is displayed. The current treatment pressure is shown in green. Events AHI per hour Apneas and hypopneas measured per hour for one day. The following sections will help with disassembling, cleaning, checking and reassembling the device. Disassembling 1. Hold the water tub at the top and bottom, press it gently and pull it away from the device.
Page Reassembling 3. Check the air filter and replace it at least every six months. Replace it more often if there are any holes or blockages by dirt or dust. To replace the air filter: 1. Open the air filter cover and remove the old air filter. The air filter is not washable or reusable. Page Reprocessing The Air Tubing 2. Run the detergent solution through the air tubing repeatedly until no contamination is visible. Thoroughly rinse each component according to the detergent manufacturer's instructions.
Page Inspecting Inspecting Perform a visual inspection of the air tubing. If any visible deterioration is apparent holes, tears or cracks etc , the air tubing should be discarded and replaced. Slight discoloration may occur and is acceptable. Packaging and storage Store in a dry, dust-free environment away from direct sunlight. Page Decontaminating 1.
Clean all components with a soft bristled brush for one minute while soaking in detergent solution see table below. Pay particular attention to all crevices and cavities. Page Reassembling Reassembling The following instructions provide guidance on how to correctly reassemble the air outlet and the water tub.
To reassemble the air outlet 1. Hold the air outlet with the seal pointing to the left and the clip pointing forward. Page 30 To reassemble the water tub lid: 1. Insert one side of the lid into the pivot hole of the base. Slide the other side down the ridge until it clicks into place.
Page Data Management And Therapy Compliance Data management and therapy compliance For therapy compliance management, the AirSense 10 device stores patient data on the device and has the ability to transfer it remotely to the care provider. Detailed Data such as snore and pulse rate, as well as high resolution flow and pressure data, are stored on the SD card. Data can be transmitted to therapy management software either remotely via cellular communication, or via SD card.
For information on purchasing, contact your ResMed representative. Do this by turning the Humidity Level to Off. Page Troubleshooting Troubleshooting If there is a problem, try the following suggestions.
If you are not able to fix the problem, contact your local ResMed dealer or ResMed office. Do not open the device. Page 35 SmartStart is enabled, but the device does not automatically stop when the patient removes their mask Incompatible mask being used. Only use equipment recommended by ResMed.
Contact ResMed or see www. If the patient is using a nasal pillows mask with set pressure Page Device Messages All other error messages, for example, System fault, refer to user guide, Error 0XX An unrecoverable error has occurred on the device.
Contact your local ResMed dealer or ResMed office. Page Technical Specifications , for residential, commercial and light industry environments. It is recommended that mobile communication devices are kept at least 1 m away from the device.
Information regarding the electromagnetic emissions and immunity of this ResMed device can be found on www. Wireless module Technology used Page 40 Humidifier performance The following settings have been tested at It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components. Page 43 ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product.
Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. Page 44 See www.
For patent and other intellectual property information, see www. Patent and Trademark Office. Actichlor is a trademark of Ecolab US Inc. Alconox is a trademark of Alconox Inc. Print page 1 Print document 44 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Don't have an account? Sign up! Restore password. Upload manual. Upload from disk.